Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Ann Thorac Surg Short Rep ; 2(1): 150-155, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38464466

ABSTRACT

BACKGROUND: We have developed a tissue engineered cardiac patch derived from a 3-dimensional (3D) myocardial tissue reinforced with extracellular matrix in an effort to enhance in situ myocardial regeneration. The feasibility of the patch was evaluated in a porcine model by various modalities to assess both the constructive and functional aspects of regeneration. METHODS: A spheroid-based 3D multicellular tissue was created using a 3D net mold system that incorporated cardiomyocytes and embryonic fibroblast cells. The 3D multicellular tissue was incorporated with extracellular matrix sheets and surgically implanted into the right ventricle of a healthy porcine model (n = 4). After 60 days, the implanted patches were evaluated by cardiac magnetic resonance imaging and electroanatomic mapping studies as well as by post-euthanasia analyses, including measurements of mechanical viscoelasticity. RESULTS: Cardiac magnetic resonance imaging revealed improved regional tissue perfusion in the patch area. Electroanatomic mapping exhibited regenerated electrical conductivity in the patch, as evidenced by relatively preserved voltage regions (1.11 ± 0.8 mV) in comparison to the normal right ventricle (4.7 ± 2.8 mV). Histologic and tissue analyses confirmed repopulation of site-specific host cells, including premature cardiomyocytes and active vasculogenesis. These findings were supported by quantitative reverse transcription-polymerase chain reaction. CONCLUSIONS: The tissue engineered cardiac patch effectively facilitated in situ constructive and functional myocardial regeneration, characterized by increased regional tissue perfusion and positive electrical activity in the porcine model.

2.
JAMA Cardiol ; 9(5): 449-456, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38536171

ABSTRACT

Importance: Current left bundle branch block (LBBB) criteria are based on animal experiments or mathematical models of cardiac tissue conduction and may misclassify patients. Improved criteria would impact referral decisions and device type for cardiac resynchronization therapy. Objective: To develop a simple new criterion for LBBB based on electrophysiological studies of human patients, and then to validate this criterion in an independent population. Design, Setting, and Participants: In this diagnostic study, the derivation cohort was from a single-center, prospective study of patients undergoing electrophysiological study from March 2016 through November 2019. The validation cohort was assembled by retrospectively reviewing medical records for patients from the same center who underwent transcatheter aortic valve replacement (TAVR) from October 2015 through May 2022. Exposures: Patients were classified as having LBBB or intraventricular conduction delay (IVCD) as assessed by intracardiac recording. Main Outcomes and Measures: Sensitivity and specificity of the electrocardiography (ECG) criteria assessed in patients with LBBB or IVCD. Results: A total of 75 patients (median [IQR] age, 63 [53-70.5] years; 21 [28.0%] female) with baseline LBBB on 12-lead ECG underwent intracardiac recording of the left ventricular septum: 48 demonstrated complete conduction block (CCB) and 27 demonstrated intact Purkinje activation (IPA). Analysis of surface ECGs revealed that late notches in the QRS complexes of lateral leads were associated with CCB (40 of 48 patients [83.3%] with CCB vs 13 of 27 patients [48.1%] with IPA had a notch or slur in lead I; P = .003). Receiver operating characteristic curves for all septal and lateral leads were constructed, and lead I displayed the best performance with a time to notch longer than 75 milliseconds. Used in conjunction with the criteria for LBBB from the American College of Cardiology/American Heart Association/Heart Rhythm Society, this criterion had a sensitivity of 71% (95% CI, 56%-83%) and specificity of 74% (95% CI, 54%-89%) in the derivation population, contrasting with a sensitivity of 96% (95% CI, 86%-99%) and specificity of 33% (95% CI, 17%-54%) for the Strauss criteria. In an independent validation cohort of 46 patients (median [IQR] age, 78.5 [70-84] years; 21 [45.7%] female) undergoing TAVR with interval development of new LBBB, the time-to-notch criterion demonstrated a sensitivity of 87% (95% CI, 74%-95%). In the subset of 10 patients with preprocedural IVCD, the criterion correctly distinguished IVCD from LBBB in all cases. Application of the Strauss criteria performed similarly in the validation cohort. Conclusions and Relevance: The findings suggest that time to notch longer than 75 milliseconds in lead I is a simple ECG criterion that, when used in conjunction with standard LBBB criteria, may improve specificity for identifying patients with LBBB from conduction block. This may help inform patient selection for cardiac resynchronization or conduction system pacing.


Subject(s)
Bundle-Branch Block , Electrocardiography , Humans , Bundle-Branch Block/physiopathology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Female , Male , Aged , Middle Aged , Prospective Studies , Retrospective Studies
3.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Article in English | MEDLINE | ID: mdl-37638389

ABSTRACT

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Cicatrix , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac , Heart Rate/physiology , Heart Block
4.
JACC Clin Electrophysiol ; 8(5): 651-661, 2022 05.
Article in English | MEDLINE | ID: mdl-35589178

ABSTRACT

OBJECTIVES: This study sought to analyze the impact of the American College of Cardiology, American Heart Association, and Heart Rhythm Society (ACC/AHA/HRS) guidelines for cardiac resynchronization therapy with defibrillator (CRT-D) update on utilization and efficacy of CRT-D. BACKGROUND: In September 2012, the ACC/AHA/HRS guidelines for CRT-D were modified to include left bundle branch block (LBBB) as a Class I indication. METHODS: The IBM Watson MarketScan Database was queried between January 1, 2003, and December 31, 2018, for CRT-D implants or upgrades. The primary outcome was heart failure (HF) hospitalization following left ventricular lead implant. Secondary outcomes included all-cause mortality and device-related lead revision. RESULTS: A total of 27,238 patients were analyzed: 18,384 pre-update and 8,854 post-update. Mean age was 69 ± 11 years, 73% men, and 98% with history of HF hospitalization. The proportion of patients with LBBB increased from 29% to 55% (P < 0.001) after the update. Patients receiving CRT-D post-update demonstrated a greater prevalence of comorbidities, including atrial fibrillation (47% vs 40%; P < 0.001), diabetes mellitus (45% vs 39%; P < 0.001), chronic kidney disease (24% vs 15%; P < 0.001), and HF hospitalization in the year before CRT-D (40% vs 37%; P < 0.001). Despite greater baseline comorbidities, HF hospitalization significantly declined post-update (HR: 0.89; P < 0.001). Multivariate predictors of reduced HF hospitalization included angiotensin receptor neprilysin inhibitor prescription (HR: 0.48; P < 0.001) and presence of LBBB (HR: 0.71; P < 0.001). All-cause mortality was not significantly different between the 2 groups, and fewer lead revisions were noted post-update (0.6% vs 1.7%; P < 0.001). CONCLUSIONS: The revised 2012 guidelines led to an increased proportion of LBBB patients receiving CRT-D at the population-level. This change was associated with reduced HF hospitalization, despite broadening therapy to patients with more comorbid conditions.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Aged , Aged, 80 and over , Arrhythmias, Cardiac/therapy , Bundle-Branch Block/epidemiology , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/adverse effects , Defibrillators, Implantable/adverse effects , Female , Heart Failure/epidemiology , Heart Failure/etiology , Heart Failure/therapy , Humans , Male , Middle Aged , Patient Selection , Treatment Outcome , United States/epidemiology
5.
Heart Rhythm ; 19(4): 527-535, 2022 04.
Article in English | MEDLINE | ID: mdl-34757186

ABSTRACT

BACKGROUND: Catheter ablation strategies for ventricular fibrillation (VF) and polymorphic ventricular tachycardia (PMVT) are not established when spontaneous triggers are rare or absent. OBJECTIVE: The purpose of this study was to report the feasibility and efficacy of a novel empiric ablation strategy of pacemapping to stored implantable cardioverter-defibrillator (ICD) template electrograms (SITE) of the clinical premature ventricular contraction (PVC) trigger. METHODS: Fifteen patients with drug-refractory VF/PMVT receiving defibrillator shocks without identifiable and mappable PVC triggers were prospectively analyzed. The protocol incorporated systematic pacemapping from known arrhythmogenic sites (moderator band/right ventricular [RV] papillary muscles, left conduction system/Purkinje network, outflow tracts) with real-time comparison between the paced ICD electrogram (EGM) morphology and SITE. RESULTS: Regions within the left Purkinje network yielded the best pacemap match for the SITE of the clinical PVC trigger in 55% of ablation targets (left posterior fascicle 6, left septal fascicle 1, left anterior fascicle 5), followed by the RV moderator band region in 14% (n = 3), RV papillary muscles in 13% (n = 3), periaortic region in 14% (n = 3), and left ventricular anterolateral papillary muscle in 4% (n = 1). Freedom from ICD therapies off antiarrhythmic drug (AAD) was 64% at 6 months and 48% at 12 months. Shock burden was reduced from 4 (2-6) to 0 (0-1) (P = .001), and use of AADs was reduced from 2 (1-2) to 0 (0-1) (P = .001). CONCLUSION: In the absence of a mappable trigger, an empiric strategy of interrogating the Purkinje network, papillary muscles, and outflow tract regions by pacemap matching with SITE of the clinical PVC is feasible to guide ablation. A significant reduction in VF/PMVT therapy burden and AAD utilization was observed after a single procedure.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Ventricular Premature Complexes , Catheter Ablation/methods , Feasibility Studies , Humans , Prospective Studies , Tachycardia, Ventricular/surgery , Ventricular Fibrillation
6.
Heart Rhythm O2 ; 2(5): 446-454, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34667959

ABSTRACT

BACKGROUND: Although His bundle pacing (HBP) has been shown to improve left ventricular ejection fraction (LVEF), its impact on mitral regurgitation (MR) remains uncertain. OBJECTIVES: The aim of this study was to evaluate change in functional MR after HBP in patients with left ventricular (LV) systolic dysfunction. METHODS: Paired echocardiograms were retrospectively assessed in patients with reduced LVEF (<50%) undergoing HBP for pacing or resynchronization. The primary outcomes assessed were change in MR, LVEF, LV volumes, and valve geometry pre- and post-HBP. MR reduction was characterized as a decline in ≥1 MR grade post-HBP in patients with ≥grade 3 MR at baseline. RESULTS: Thirty patients were analyzed: age 68 ± 15 years, 73% male, LVEF 32% ± 10%, 38% coronary artery disease, 33% history of atrial fibrillation. Baseline QRS was 162 ± 31 ms: 33% left bundle branch block, 37% right bundle branch block, 17% paced, and 13% narrow QRS. Significant reductions in LV end-systolic volume (122 mL [73-152 mL] to 89 mL [71-122 mL], P = .006) and increase in LV ejection fraction (31% [25%-37%] to 39% [30%-49%], P < .001) were observed after HBP. Ten patients had grade 3 or 4 MR at baseline, with reduction in MR observed in 7. In patients with at least grade 3 MR at baseline, reduction in LV volumes, improved mitral valve geometry, and greater LV contractility were associated with MR reduction. Greater reduction in paced QRS width was present in MR responders compared to non-MR responders (-40% vs -25%, P = .04). CONCLUSIONS: In this initial detailed echocardiographic analysis in patients with LV systolic dysfunction, HBP reduced functional MR through favorable ventricular remodeling.

7.
Pacing Clin Electrophysiol ; 44(9): 1549-1561, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34245025

ABSTRACT

BACKGROUND: Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity and mortality making the identification of the causative organism critical. The vast majority of CIED infections are caused by Staphylococcal species. CIED infections associated with atypical pathogens are rare and have not been systematically investigated. The objective of this study is to characterize the clinical course, management and outcome in patients with CIED infection secondary to atypical pathogens. METHODS: Medical records of all patients who underwent CIED system extraction at the University of Chicago Medical Center between January 2010 and November 2020 were retrospectively reviewed to identify patients with CIED infection. Demographic, clinical, infection-related and outcome data were collected. CIED infections were divided into typical and atypical groups based on the pathogens isolated. RESULTS: Among 356 CIED extraction procedures, 130 (37%) were performed for CIED infection. Atypical pathogens were found in 5.4% (n = 7) and included Pantoea species (n = 2), Kocuria species (n = 1), Cutibacterium acnes (n = 1), Corynebacterium tuberculostearicum (n = 1), Corynebacterium striatum (n = 1), Stenotrophomonas maltophilia (n = 1), and Pseudozyma ahidis (n = 1). All patients with atypical CIED infections were successfully treated with total system removal and tailored antibiotic therapy. There were no infection-related deaths. CONCLUSIONS: CIED infections with atypical pathogens were rare and associated with good outcome if diagnosed early and treated with total system removal and tailored antimicrobial therapy. Atypical pathogens cultured from blood, tissue or hardware in patients with CIED infection should be considered pathogens and not contaminants.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Defibrillators, Implantable/adverse effects , Device Removal , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/therapy , Aged , Combined Modality Therapy , Female , Humans , Male , Middle Aged
8.
Heart Rhythm ; 18(9): 1548-1556, 2021 09.
Article in English | MEDLINE | ID: mdl-33965607

ABSTRACT

BACKGROUND: The classical paradigm of scar-related reentrant ventricular tachycardia (VT) features a circuit with a double loop figure-of-eight (F8) activation pattern. OBJECTIVE: The purpose of this study was to interrogate VT circuits with F8 activation patterns by entrainment mapping to differentiate an active loop from a passive loop. METHODS: Sixty VT circuits with >90% of tachycardia cycle length delineated in high resolution were retrospectively analyzed in 55 patients (nonischemic 49%). A pseudo-F8 VT circuit was defined as a double loop activation pattern driven by a single loop mechanism with a passive loop that yields a long postpacing interval (postpacing interval - tachycardia cycle length ≥ 30 ms). RESULTS: Single loop activation patterns were observed in 33% (n = 20). Of 40 circuits with F8 patterns by activation mapping, 20 were studied with entrainment mapping, where a passive loop was identified by a long postpacing interval in 50%. In 6 circuits where entrainment mapping was performed from both outer loop regions, all demonstrated asymmetric responses to entrainment, confirming a single loop mechanism. Entrainment from both lateral margins of the common pathway (n = 7) demonstrated an asymmetric response in 29%. In all pseudo-F8 circuits (n = 10), the shorter loop functioned as the active loop and ablation targeting the active loop side of the isthmus resulted in VT termination with a single radiofrequency application. CONCLUSION: In a selected cohort, single loop mechanisms are more prevalent than double loop reentry in reentrant human VT. Half of VT circuits with double loop activation patterns can be demonstrated to be sustained by a single active loop mechanism by entrainment mapping. Ablation targeting the shorter active loop resulted in rapid termination during radiofrequency application.


Subject(s)
Body Surface Potential Mapping/methods , Heart Conduction System/physiopathology , Heart Rate/physiology , Tachycardia, Ventricular/physiopathology , Aged , Catheter Ablation/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Tachycardia, Ventricular/surgery
9.
Heart Rhythm ; 18(6): 916-925, 2021 06.
Article in English | MEDLINE | ID: mdl-33524624

ABSTRACT

BACKGROUND: While advances in the characterization of the structural substrate in arrhythmogenic right ventricular cardiomyopathy (ARVC) have been made, the ventricular tachycardia (VT) circuit remains incompletely described. OBJECTIVE: The purpose of this study was to delineate the reentrant VT circuit with simultaneous epicardial and endocardial mapping (SEEM) in ARVC. METHODS: Twenty-three consecutive patients with ARVC and VT underwent SEEM at 4 centers between 2014 and 2020. Retrospective analysis was performed on combined isochronal activation maps. RESULTS: Of the 30 VT circuits, 24 were delineated with SEEM (956 [341-1843] endocardial points and 1763 [882-3054] epicardial points). The apex and outflow tract rarely harbored VT circuits, with 50% distributed in the inferior wall and 43% in the free wall. The entire tachycardia cycle length was recorded from the epicardium in 71% of circuits. In all circuits, a large proportion of the tachycardia cycle length was recorded from the epicardium relative to the endocardium. Localized epicardial reentry was observed in 35% of patients (14 mm × 15 mm), which was associated with smaller endocardial low voltage area (39 cm2 vs 104 cm2; P = .002) and preserved right ventricular ejection fraction (35% vs 25%; P = .046) compared with those with larger circuit dimensions. Seventy percent of termination sites were achieved from the epicardium. CONCLUSION: High-resolution recordings from both myocardial surfaces confirm a consistent predominance of epicardial participation during reentry in ARVC. Only the perivalvular inflow region of the "triangle of dysplasia" had a strong propensity to harbor VT circuits, with the greatest proportion located in the inferior wall. Localized epicardial reentry may be a manifestation of earlier stage disease with a relative paucity of endocardial substrate.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Catheter Ablation/methods , Epicardial Mapping/methods , Tachycardia, Ventricular/physiopathology , Adult , Aged , Arrhythmogenic Right Ventricular Dysplasia/etiology , Arrhythmogenic Right Ventricular Dysplasia/surgery , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Tachycardia, Ventricular/complications , Young Adult
10.
Cureus ; 13(1): e12702, 2021 Jan 14.
Article in English | MEDLINE | ID: mdl-33604224

ABSTRACT

Background The CanGaroo® Envelope (Aziyo Biologics, Silver Spring, MD) is intended to securely hold a cardiovascular implantable electronic device (CIED) to create a stable environment when implanted in the body. Data on the utilization of this newly available product are limited. Objective In this study, our objective was to describe the specific profiles of patients who may benefit from the use of the CanGaroo® Envelope at the time of CIED implantation. Methods  The utilization of the CanGaroo® Envelope was assessed from January 2019 to October 2019 among a series of patients who were either undergoing de-novo CIED implantation or replacement. Results Among a total of 50 patients, the CanGaroo® Envelope was utilized in 15 (30%). Three distinct patient profiles were identified: profile 1: elderly patients with poor tissue turgor at risk of wound dehiscence or erosion; profile 2: patients with a history of previous device infection; and profile 3: patients at high risk of device infection having one or more of the following risk factors - chronic kidney disease, immunocompromised state, or diabetes mellitus. At a mean follow-up of 18 ±3 months, no CIED pocket erosion, dehiscence, or infection was noted. Conclusions Three distinct profiles of patients who could potentially benefit from the use of the CanGaroo® Envelope were identified by the implanting physicians. Long-term follow-up data, including infection and wound dehiscence rates, are necessary to further analyze the optimal utilization of the device.

11.
Heart Rhythm ; 18(1): 10-19, 2021 01.
Article in English | MEDLINE | ID: mdl-32707175

ABSTRACT

BACKGROUND: While early precordial electrocardiographic (ECG) characteristics are useful to differentiate left-sided from the right-sided outflow tract ventricular arrhythmia (OTVA), few patterns predict an origin from the septal margin of the left ventricular (LV) summit. OBJECTIVE: The purpose of this study was to report mapping and ablation characteristics of a new ECG pattern with left bundle branch morphology and an abrupt R-wave transition in lead V3 (ATV3). METHODS: Over a 3-year period, 78 consecutive patients (mean age 57±15 years; 35% female) with OTVA were referred for mapping and ablation. Twenty patients (26%) exhibited an ATV3 pattern, of whom 65% failed prior ablation. RESULTS: Ninety-two percent of patients with ATV3 that underwent simultaneous epicardial and endocardial mapping demonstrated an intramural or epicardial site of origin. Eighty percent of OTVA with ATV3 was eliminated by ablation from the vantage point of the interleaflet triangle below the right-left coronary junction. The ATV3 pattern showed higher sensitivity, specificity, predictive value, and accuracy than validated ECG criteria (notch or "w" pattern in lead V1, qrS pattern in leads V1 through V3, and pattern break V2) for predicting successful ablation in the region of the anterior LV ostium. At 12±11 months, freedom from ventricular arrhythmia recurrence was 89% and 82% in the ATV3 and control groups, respectively. CONCLUSION: ATV3 is a simple and distinct ECG pattern indicative of a site of origin from the septal margin of the LV summit. The right-left aortic interleaflet triangle vantage point was effective to eliminate OTVA with ATV3 that overwhelmingly exhibited the earliest activation from the epicardium or mid-myocardium. Test characteristics for ATV3 were superior to ECG patterns validated for the anterior LV ostium.


Subject(s)
Electrocardiography , Heart Conduction System/physiopathology , Heart Rate/physiology , Heart Ventricles/physiopathology , Tachycardia, Ventricular/diagnosis , Action Potentials/physiology , Adult , Aged , Aged, 80 and over , Catheter Ablation , Female , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery
12.
Indian Pacing Electrophysiol J ; 21(2): 124-127, 2021.
Article in English | MEDLINE | ID: mdl-33271274

ABSTRACT

Permanent pacemaker (PPM) malfunction due to electrical connection problems such as a loose set screw or lead-header malapposition is extremely rare. We present a patient with complete heart block (CHB) who had PPM malfunction and recurrent syncope, late (14 months) after initial implantation, which was caused by the ventricular lead pin disengagement from the header resulting in oversensing due to noise, pacing inhibition and recurrent syncope. PPM due to lead-header malapposition this late after device implantation has previously not been reported.

13.
Circulation ; 143(3): 212-226, 2021 01 19.
Article in English | MEDLINE | ID: mdl-33169628

ABSTRACT

BACKGROUND: Fast ventricular tachycardias (VTs) have historically been attributed to shorter path lengths with smaller reentrant circuit dimensions in animal models. The relationship between the dimensions of the reentrant VT circuit and tachycardia cycle length (TCL) has not been examined in humans. This study aimed to analyze the determinants of the rate of human VT with comparison of circuit dimensions and conduction velocity (CV) across a wide range of both stable and unstable VTs delineated by high-resolution mapping. METHODS: Fifty-four VTs with complete circuit delineation (>90% TCL) by high-resolution multielectrode mapping were analyzed in 49 patients (men, 88%; age, 65 years [58-71 years]; nonischemic, 47%). Fast VT was defined as TCL <333 milliseconds (rate >180 bpm). Unstable VT was defined by hemodynamic deterioration with an intrinsic mean arterial pressure <60 mm Hg during a sustained episode. RESULTS: The median TCL of VT was 365 milliseconds (306-443 milliseconds), and 24 fast VTs were characterized. A wide range of CVs was observed within the entrance (0.03-0.55 m/s), common pathway (0.03-0.77 m/s), exit (0.03-0.53 m/s), and outer loop (0.17-1.13 m/s). There were no significant differences in the median dimensions of the isthmus and path length between fast and slow VTs and between unstable and stable VTs. The outer loop CV was the only circuit component that correlated with TCL in both ischemic cardiomyopathy (r=-0.5, P=0.006) and nonischemic cardiomyopathy (r=-0.45, P=0.028). The duration of the longest diastolic electrogram was inversely correlated with the dimensions of common pathway (length: r=-0.46, P=0.001, width: r=-0.3, P=0.047) and predictive of rapid VT termination by a single radiofrequency application (r=-0.41, P=0.023). CONCLUSIONS: Because of a wide spectrum of CV observed within the reentrant path during human VT, the dimensions of the circuit were not predictive of VT cycle length. For the first time, we demonstrate that the CV of the outer loop, rather than isthmus, is the principal determinant of the rate of VT. The size of the circuit was similar between fast and slow VTs and between unstable and stable VTs. Long, continuous electrograms were indicative of spatially confined isthmus dimensions, confirmed by rapid termination of VT during radiofrequency delivery.


Subject(s)
Body Surface Potential Mapping/methods , Heart Conduction System/physiopathology , Heart Rate/physiology , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/physiopathology , Aged , Catheter Ablation/methods , Female , Humans , Male , Middle Aged , Retrospective Studies , Tachycardia, Ventricular/surgery
14.
JACC Clin Electrophysiol ; 6(14): 1812-1823, 2020 12.
Article in English | MEDLINE | ID: mdl-33357578

ABSTRACT

OBJECTIVES: This study sought to describe arrhythmia characteristics using ultra-high density (UHD) mapping of macro-re-entrant left atrial flutter (LAFL) which propagate via epicardial bridging (EB), and highlight regional anatomy that poses challenges to ablation. BACKGROUND: Three-dimensional propagation via EB may contribute to the maintenance and complexity of LAFL. METHODS: UHD activation maps of macro-re-entrant LAFL created with a mini-electrode basket catheter were analyzed between June 2015 and March 2020. EB was defined as a region of wave front discontinuity with focal activation distal to an activation gap. Regions of EB were correlated with anatomic structures known to have specialized epicardial bundles. Direct evidence of EB was obtained via percutaneous epicardial access (n = 22) with simultaneous epicardial recordings during endocardial activation gaps. RESULTS: Among 159 patients who underwent LA endocardial procedures with UHD mapping, 43 patients with 47 macro-re-entrant LAFLs were included in this analysis. Evidence of EB was present in 38% of LAFLs. Four anatomic areas of EB were observed: coronary sinus (17%), vein of Marshall (28%), Bachmann's region (33%), and region of the septopulmonary bundle (22%). All 47 LAFLs were successfully ablated. Percutaneous epicardial mapping yielded direct evidence for EB in 9 patients with LAFL (41%). At 23 ± 13 months, 70% remained free from recurrent LAFL. CONCLUSIONS: In a selected population, UHD mapping demonstrates evidence of EB in 38% of cases of LAFL involving 4 distinct epicardial anatomic regions. Identification of discontinuous 3-dimensional activation patterns with attention to correlative regional LA anatomy may reduce the incidence of ablation failures for complex re-entry.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Atrial Fibrillation/surgery , Atrial Flutter/surgery , Endocardium , Heart Atria , Humans
15.
Circ Arrhythm Electrophysiol ; 13(8): e007726, 2020 08.
Article in English | MEDLINE | ID: mdl-32628867

ABSTRACT

BACKGROUND: Clinical factors associated with development of intravascular lead adherence (ILA) are unreliable predictors. Because vascular injury in the superior vena cava-right atrium during transvenous lead extraction is more likely to occur in segments with higher degrees of ILA, reliable and accurate assessment of ILA is warranted. We hypothesized that intravascular ultrasound (IVUS) could accurately visualize and quantify ILA and degree of ILA correlates with transvenous lead extraction difficulty. METHODS: Serial imaging of leads occurred before transvenous lead extraction using IVUS. ILA areas were classified as high or low grade. Degree of extraction difficulty was assessed using 2 metrics and correlated with ILA grade. Lead extraction difficulty was calculated for each patient and compared with IVUS findings. RESULTS: One hundred fifty-eight vascular segments in 60 patients were analyzed: 141 (89%) low grade versus 17 (11%) high grade. Median extraction time (low=0 versus high grade=97 seconds, P<0.001) and median laser pulsations delivered (low=0 versus high grade=5852, P<0.001) were significantly higher in high-grade segments. Most patients with low lead extraction difficulty score had low ILA grades. Eighty-six percentage of patients with high lead extraction difficulty score had low IVUS grade, and the degree of transvenous lead extraction difficulty was similar to patients with low IVUS grades and lead extraction difficulty scores. CONCLUSIONS: IVUS is a feasible imaging modality that may be useful in characterizing ILA in the superior vena cava-right atrium region. An ILA grading system using imaging correlates with extraction difficulty. Most patients with clinical factors associated with higher extraction difficulty may exhibit lower ILA and extraction difficulty based on IVUS imaging. Graphic Abstract: A graphic abstract is available for this article.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Ultrasonography, Interventional , Vena Cava, Superior/diagnostic imaging , Aged , Aged, 80 and over , Device Removal/adverse effects , Feasibility Studies , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Risk Assessment , Risk Factors , Treatment Outcome , Vascular System Injuries/etiology , Vena Cava, Superior/injuries
16.
Heart Rhythm ; 17(8): 1271-1279, 2020 08.
Article in English | MEDLINE | ID: mdl-32325198

ABSTRACT

BACKGROUND: The mechanisms for scar-related ventricular tachycardia (VT) originating from the periaortic region remain incompletely characterized. OBJECTIVE: The purpose of this study was to map the circuits responsible for periaortic VT in high resolution. METHODS: Cases with periaortic VT (2016-2020) were analyzed to characterize the substrate and mechanisms with multielectrode mapping. Periaortic VT was defined as low-voltage and/or deceleration zones within 2 cm of the left ventriculoaortic junction with a corresponding critical site during VT. RESULTS: Forty-nine periaortic monomorphic VTs were analyzed in 30 patients (25% of all patients with nonischemic cardiomyopathy). Isolated periaortic substrate was observed in 27% of patients, with 73% having concomitant scar, most commonly in the mid-septum (47%). Deceleration zones were equally prevalent on the septal and lateral portions of the periaortic region (87% vs 73%; P = .19). During activation mapping of VT (tachycardia cycle length 392 ± 105 ms), localized reentrant patterns of activation (14 mm [10-17 mm] × 10 mm [7-14 mm]) were demonstrated in 63% and 37% of VTs showed centrifugal activation, consistent with a focal breakout pattern. Ninety-three percent of VTs fulfilled criteria for a reentrant mechanism. Sixty-five percent of reentrant circuits had endocardial activation gaps within the tachycardia cycle length (3-dimensional circuitry), which were associated with higher rates of recurrence as compared with 2-dimensional complete circuits at 1 year (73% vs 37%; P = .028). CONCLUSION: Periaortic VTs were observed in 25% of patients with nonischemic cardiomyopathy and scar-related VT. For the first time, localized reentry confined to this anatomically challenging region was demonstrated as the predominant mechanism by high-resolution circuit activation mapping.


Subject(s)
Cicatrix/complications , Heart Conduction System/physiopathology , Heart Ventricles/physiopathology , Tachycardia, Ventricular/physiopathology , Aged , Catheter Ablation/methods , Cicatrix/physiopathology , Electrophysiologic Techniques, Cardiac , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery
17.
Pacing Clin Electrophysiol ; 43(5): 527-533, 2020 05.
Article in English | MEDLINE | ID: mdl-32259298

ABSTRACT

Conventional treatment strategies for catecholaminergic polymorphic ventricular tachycardia (CPVT) include avoidance of strenuous exercise and competitive sports, drugs such as ß-blockers and flecainide and, cervical sympathectomy. An implantable cardioverter-defibrillator (ICD) has been utilized if the response to these strategies is inadequate; however, ICD use in CPVT patients, in addition to usual complications, is associated with an increased risk of life-threatening electrical storm. Ivabradine is a selective inhibitor of hyperpolarization-activated cyclic nucleotide-gated potassium channel 4 generated funny current (If ), which has been shown to be efficacious in suppression of inappropriate sinus tachycardia, junctional tachycardia, atrial tachycardia, and ventricular ectopy in humans. We report an 18-year-old male with a severe CPVT phenotype refractory to flecainide, nadolol, and sympathectomy who exhibited suppression of ventricular arrhythmias after initiation of ivabradine. These findings are of importance as ivabradine could be an important add-on therapy in CPVT patients who are drug refractory or are unable to continue conventional therapies at the recommended doses.


Subject(s)
Cardiovascular Agents/therapeutic use , Ivabradine/therapeutic use , Tachycardia, Ventricular/drug therapy , Adolescent , Electrocardiography , Exercise Test , Flecainide/therapeutic use , Humans , Male , Nadolol/therapeutic use , Phenotype , Sympathectomy , Tachycardia, Ventricular/surgery
18.
JACC Clin Electrophysiol ; 6(3): 311-323, 2020 03.
Article in English | MEDLINE | ID: mdl-32192682

ABSTRACT

OBJECTIVES: This study aimed to evaluate the feasibility and accuracy of using a novel grid mapping catheter during scar-related ventricular tachycardia (VT) ablation. BACKGROUND: Ultra-high-density (UHD) mapping improves identification of local abnormal ventricular activities (LAVAs) and characterization of scar substrates. METHODS: Consecutive patients underwent endocardial and/or epicardial ablation guided by a HD grid mapping catheter. A linear duodecapolar catheter was used in the initial cases for systematic correlation. Isochronal late activation mapping was performed during sinus rhythm to identify deceleration zones, and activation mapping of VT was performed when tolerated. RESULTS: In 38 patients, 51 electroanatomic maps (left ventricle: 26, epicardium: 21, right ventricle: 4) were created using a grid catheter. LAVAs were identified in 98% of cases and deceleration zones were observed in 86%. High-frequency electrograms with diastolic activation were identified during 44 sustained monomorphic VTs, and the critical isthmus was colocalized to deceleration zones during sinus rhythm in 96% of cases. In 17 cases that underwent sequential mapping with both grid and linear catheters, the low voltage area detected using the grid (HD wave) was significantly smaller, with ratios of 0.61 (<0.5 mV) and 0.81 (<1.5 mV) relative to the duodecapolar catheter. CONCLUSIONS: VT ablation guided by a novel HD grid catheter is safe and feasible for clinical use in human scar-related VT via both endocardial and epicardial approaches. Automated selection of larger bipolar amplitudes among orthogonal pairs consistently displayed smaller low voltage areas than a previously validated linear catheter.


Subject(s)
Catheter Ablation/methods , Tachycardia, Ventricular/surgery , Aged , Catheter Ablation/instrumentation , Electrophysiologic Techniques, Cardiac , Feasibility Studies , Female , Heart/diagnostic imaging , Heart/physiopathology , Humans , Male , Middle Aged , Tachycardia, Ventricular/diagnostic imaging
19.
J Am Coll Cardiol ; 75(8): 884-897, 2020 03 03.
Article in English | MEDLINE | ID: mdl-32130924

ABSTRACT

BACKGROUND: Mechanisms of scar-related ventricular tachycardia (VT) are largely based on computational and animal models that portray a 2-dimensional view. OBJECTIVES: The authors sought to delineate the human VT circuit with a 3-dimensional perspective from recordings obtained by simultaneous endocardial and epicardial mapping. METHODS: High-resolution mapping was performed during 97 procedures in 89 patients with structural heart disease. Circuits were characterized by systematic isochronal analysis to estimate the dimensions of the isthmus and extent of the exit region recorded on both myocardial surfaces. RESULTS: A total of 151 VT morphologies were mapped, of which 83 underwent simultaneous endocardial and epicardial mapping; 17% of circuits activated in a 2-dimensional plane, restricted to 1 myocardial surface. Three-dimensional activation patterns with nonuniform transmural propagation were observed in 61% of circuits with only 4% showing transmurally uniform activation, and 18% exhibiting focal activation patterns consistent with mid-myocardial reentry. The dimensions of the central isthmus were 17 mm (12 to 28 mm) × 10 mm (9 to 19 mm) with 55% exhibiting a minimal dimension of <1.5 cm. QRS activation was transmural in 63% and located 43 mm (34 to 52 mm) from the central isthmus. On the basis of 6 proposed definitions for epicardial VT, the prevalence of an epicardial circuit ranged from 21% to 80% in ischemic cardiomyopathy and 28% to 77% in nonischemic cardiomyopathy. CONCLUSIONS: A 2D perspective oversimplifies the electrophysiological circuit responsible for reentrant human VT and simultaneous endocardial and epicardial mapping facilitates inferences about mid-myocardial activation. Intricate activation patterns are frequently observed on both myocardial surfaces, and the epicardium is functionally involved in the majority of circuits. Human reentry may exist within isthmus dimensions smaller than 1 cm, whereas QRS activation is often transmural and remote from the critical isthmus target. A 3-dimensional perspective of the VT circuit may enhance the precision of ablative therapy and may support a greater role for adjunctive strategies and technology to address arrhythmogenic tissue harbored in the mid-myocardium and subepicardium.


Subject(s)
Epicardial Mapping/methods , Tachycardia, Ventricular/physiopathology , Aged , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Retrospective Studies
SELECTION OF CITATIONS